Page 7-54 Section 7 – Adjustment, Repair, and Replacement CFP83 Series Coolant Thermostat Removal/Installation (Cont) NOTE : If the thermostats and shims may be reused, separate and tag the shims along with the associated thermostats. Remove both thermostats and any shims. Inspect for Reuse Inspect the thermostats for damage. Make sure both thermostats are clean and free from corrosion. Suspend the thermostats and a 100°C [212°F] thermometer in a container of water. NOTE : Do not allow the thermostats or thermometer to touch the container. Heat the water slowly so the wax element in the thermostats has sufficient time to react to the rising water temperature. NOTE :
The normal operating temperature is stamped on the thermostat. Inspect the thermostats as follows: Thermostat must begin to open within 1°C [2°F] of 82°C [180°F]. Thermostat must be fully open within 1°C [2°F] of 95°C [203°F]. NOTE : The fully open clearance between the thermostat flow valve and flange must be 41.5 mm [1.63 in] minimum. Drawing No. 9777, Section 7, Rev. 02-07