Section 7– Adjustment, Repair, and Replacement Page 7-73 CFP83 Series Battery Isolator Removal/Installation (Cont) Drawing No. 9777, Section 7, 02-07 Disconnect the battery cable from terminal 1. Disconnect the battery cable from terminal 2. Disconnect the alternator cable from terminal A. Disconnect the alternator excitation cable from terminal E. Remove the four mounting nuts and the battery isolator. Install Align and position the battery isolator on the four mounting studs. Install the four mounting nuts. Torque Value: As per capscrew markings and torque values in Section 10 Connect the battery cable at terminal 1. Connect the battery cable at terminal 2.
Connect the alternator cable at terminal A. Connect the alternator excitation cable at terminal E. Ensure that all four rubber caps are in position. Follow-Up NOTE: Refer to Battery Removal/Installation in this section for detailed instructions for connecting the battery cable clamps. Connect the negative battery cable at Battery A. Connect the negative battery cable at Battery B.