Page 7-82 Section 7 – Adjustment, Repair, and Replacement CFP83 Series Battery Testing (Cont) Drawing No. 9777, Section 7, Rev. 02-07 Check Battery Output CAUTION Do not connect battery charging cables to any electronic control system part. This can damage the electronic control system parts. NOTE: Use the inductive charging-cranking systems analyzer, Cummins Part Number 3377193, to test the output amperage of either maintenance-free or conventional vent cap batteries. Follow the instructions provided with the test equipment. NOTE: The required battery output in cold cranking amperes is provided in Electrical System Specifications in Section 10. Use the listed value for the system voltage.
Test both sets of batteries. NOTE: For customer supplied batteries, refer to the manufacturer's literature for charging instructions. If the output amperage is low, charge the battery. Refer to Battery and Electrical Installation in Section 3. Replace the battery if it will not charge to the manufacturer's specifications or will not maintain a charge. For safety reasons, both batteries must be re- connected before putting the engine and fire protection system controller back in service. Wear safety glasses when reconnecting batteries! Reconnect the batteries at their terminals after all service work has been completed.