Cummins — Cummins CFP83 Series Fire Pump Drive Engines Operation & Maintenance Manual

Page 7-86 Section 7 – Adjustment, Repair, and Replacement CFP83 Series Battery Removal/Installation (Cont) Drawing No. 9777, Section 7, Rev. 02-07 Install NOTE: Use the correct battery tools. Use a battery cable clamp spreader to install tight cable clamps on the battery terminal. Use end wrenches to tighten the battery clamps WARNING Do not tip the battery and spill the acid. Using a battery carrier, carry and position the battery. WARNING To reduce the possibility of arcing, attach the negative (-) battery cable last. Spread the positive cable clamp and position the clamp on the post. Tighten the positive cable clamp. Spread the negative cable clamp and position the clamp on the post.

Tighten the negative cable clamp. Torque Value: As per capscrew markings and torque values in Section 10. Install any battery support hardware. Follow-Up If new batteries are installed, charge the batteries. Refer to Battery and Electrical Installation in Section 3. For safety reasons, both batteries must be re- connected before putting the engine and fire protection system controller back in service. Wear safety glasses when reconnecting batteries! Reconnect the batteries at their terminals after all service work has been completed.