Page 7-118 Section 7 – Adjustment, Repair, and Replacement CFP83 Series Fuel Injection Pump, In-Line, Spill Port Timing (Cont) CAUTION If a replacement or repaired pump was installed, be sure to fill the governor housing with clean lubricating engine oil before starting the engine. Failure to do so will result in damage to the governor fly weights. Remove the access plug, and fill the governor housing with clean lubricating engine oil using specifications below. Oil Capacities: RQVK Governor 750 ml [0.71 qt] RQV Governor 750 ml [0.71 qt] RSV Governor 450 ml [0.48 qt] Bosch RSV-H Governor 500 ml [0.53 qt] Denso Install the access plug. Torque Value: 28 N•m [21 ft-lb] Follow-Up Drawing No.
9777, Section 7, Rev. 02-07