Page 7-170 Section 7 – Adjustment, Repair, and Replacement CFP83 Series Turbocharger Removal/Installation (Cont) If loosened, tighten the turbine housing capscrews. Bend the lockplates onto the flats to prevent loosening. Torque Value: 20 N•m [15 ft-lb] If required, loosen the compressor housing, and position the housing to align with the crossover tube. Torque Value: 9 N•m [80 in-lb] Tighten the band clamp. Tap around the clamp with a plastic hammer and tighten again. Torque Value: 9 N•m [80 in-lb] CAUTION To prevent bearing damage, new turbochargers must be pre-lubricated before start-up. Pour 50 to 60 cc [3 to 4 oz] of clean lubricating engine oil into the oil supply fitting.

Rotate the turbine wheel to allow the oil to enter the bearing housing. Drawing No. 9777, Section 7, Rev. 02-07