Section 7 – Adjustment, Repair, and Replacement Page 7-171 CFP83 Series Turbocharger Removal/Installation (Cont) Install the exhaust outlet connection. Do not tighten the two mounting capscrews until the band clamp has been tightened. Torque Values: Band Clamp 8 N•m [71 in-lb] Capscrews 43 N•m [32 ft-lb] CAUTION When installing the oil supply line, be sure the line is not in direct contact with the turbine housing or the line will burn during operation. Install the oil supply line. Torque Value: 35 N•m [26 ft-lb] If equipped with a wastegate turbocharger, install the intake manifold pressure supply line from the boost capsule. Drawing No. 9777, Section 7, Rev. 02-07