Section 12 – Troubleshooting Page 12-33 CFP83 Series Engine Cranks Normally But Will Not Start (No Exhaust Smoke) Drawing No. 9777, Section 12, Rev. 02-07 Cause Correction No fuel in supply tank. Check and replenish fuel supply. Check fittings and hose connections and hose conditions. Air is in the fuel system. Check for air in the fuel system. Tighten or replace the fuel connections, fuel lines, fuel tank standpipe and fuel filters as necessary. Vent air from the system. Refer to Air in Fuel in Section 7. Fuel Shutoff Valve (FSOV) fails to open. If the fuel shutoff valve is not functioning, manually override it. Refer to Emergency Starting With Failed Fuel Shut-Off Solenoid in Section 3.
When practical, check the wiring for electrical faults. Refer to Drawing 10423 Sheet 2 in Section 13. If the wiring is OK, replace the Fuel Shutoff Valve. Refer to Fuel Shutoff Valve (FSOV) Removal/ Installation in Section 7. Fuel grade is not correct for the application or the fuel quality is poor. Operate the engine from a tank of high-quality fuel. Refer to Fuel Recommendations and Specifications in Section 10. Fuel connections on the suction side of the fuel lift pump are loose. Tighten all the fuel fittings and connections between the fuel tanks and fuel lift pump.