Cummins — Cummins CFP83 Series Fire Pump Drive Engines Operation & Maintenance Manual

Section 12 – Troubleshooting Page 12-95 CFP83 Series Lubricating Oil Sludge in the Crankcase Excessive Drawing No. 9777, Section 12, Rev. 02-07 Cause Correction Bulk oil supply is contaminated. Check the bulk oil supply. Replace it is necessary. Refer to Lubricating Oil Recommendations and Specifications in Section 10. Drain the oil and replace with non-contaminated oil. Also, replace the oil filter. Refer to Change Lubricating Oil and Filters in Section 7. Coolant temperature is below specification. Refer to the Coolant Temperature Below Normal (Engine Running) symptom tree in this section. Crankcase ventilation system is plugged. Check and clean the crankcase breather and vent tube.

Refer to Rocker Lever (003-008) in Troubleshooting and Repair Manual C Series Engines, Bulletin Number 3666003-02. Fuel grade is not correct for the application or the fuel quality is poor. Operate the engine from a tank of high-quality fuel. Refer to Fuel Recommendations and Specifications in Section 10. Lubricating oil does not meet specifications for operating conditions. Check the grade and type of oil. Refer to Lubricating Oil Recommendations and Specifications in Section 10. If the wrong type or grade of oil is present, drain and replace it. Refer to Change Lubricating Oil and Filters in Section 7. Lubricating oil drain interval is excessive.

Verify the correct lubricating oil drain interval. Refer to Change Lubricating Oil and Filters in Section 7.