Section 3 – Installation and Operation Page 3-23 CFP83 Series Pre-Lubricate the Engine (CFP83-F40) Check content, option info not found/available Disconnect the connector at the electric fuel solenoid. Press the MANUAL position on the AUTO/MANUAL rocker switch. NOTE : Monitor engine oil pressure on the local control panel. Some pressure indication is expected. Crank the engine about two revolutions using either the CRANK BATT A or the CRANK BATT B switch positions. Repeat a second time if oil pressure did not register on the gauge. NOTE : Troubleshoot as per Lubricating Oil Pressure Low in Section 12 if oil pressure did not register on the gauge.
When pre-lubrication has been accomplished, reconnect the connector at the fuel injection pump solenoid. Drawing No. 9777, Section 3, Rev. 02-07