CNH T8000 — PFC AXIAL PISTON PUMP

Section 35 - Hydraulic Systems, 3PT - Chapter 2 18 19 21 1 15 16 4 2 17 3 1. SIGNAL LINE PRESSURE 14. OUTLET PORT (NOT SHOWN) 18. FLOW COMPENSATOR SPOOL RH02B010 2. PUMP CASE DRAIN 15. FLOW COMPENSATOR SPOOL 19. HIGH PRESSURE COMPENSATOR SPOOL 3. CONTROL PISTON PRESSURE 16. HIGH PRESSURE COMPENSATOR SPOOL 21. COMPENSATOR ASSEMBLY 4. PISTON PUMP OUTLET PRESSURE 17. HIGH PRESSURE SPRING Pressure and Flow Delivery and Compensation Principle When oil is required in the system, the flow is controlled by the difference in pressure at opposite ends of the compensator spool. When a control valve is operated, pressure at the outlet of the piston pump will drop slightly.

This will enable the spring and signal line pressure to shift the flow compensator spool away from the spring end, allowing oil from the control piston to drain past the spool land to tank. As the oil drains out of the control piston, the swash plate angle will increase and the pump flow will rise until the flow demand has been met. The flow from the pump is determined by the size of the orifice in the control valve which is being operated. This orifice is created by limiting the main valve spool travel within the control valve. When a control valve is operated, the oil pressure in the circuit being supplied will increase to its operating pressure.

This pressure will be transmitted through the sensing line to the spring end of the compensator spool. 35-2-38