Section 35 - Hydraulic Systems, 3PT - Chapter 2 Increased Flow Demand When an additional control valve is operated, it will cause a slight pressure drop at the pump pressure passage. The compensator spool will move up and allow the oil behind the control piston to drain to tank. The swash plate will move and the pump flow will be increased until the extra demand for flow has been met. Pressure at the pump outlet will increase until it is 340 to 390 psi (23.5 to 27 bar) above the signal line pressure. This increase in pressure will move the pump compensator spool against the spring allowing sufficient flow past the spool to the control piston.
This will move the swash plate to a position where the increased flow is maintained and the pressure stabilized. Decreased Flow Demand If there is a reduction in the demand for flow, pump pressure will increase until the pump outlet pressure exceeds the signal line pressure by more than 340 to 390 psi (23.5 to 27 bar). This will cause the flow compensator spool to move down to allow some oil to flow into the pump control piston. This will destroke the pump against the spring and thus reduce the pump flow. When the pump flow has fallen to match the demand, the difference in pressure felt on the opposite ends of the pump compensator spool will return to 340 to 390 psi (23.5 to 27 bar).
The pump compensator spool will then reposition itself to block off the passage to the control piston. This will lock the swash plate at that pumping angle. 35-2-39