CNH T8000 — AUTOMATIC TEMPERATURE CONTROL (ATC) OPERATION

Section 50 - Climate Control - Chapter 1 ATC Fault Code 121 Temperature select pot open or shorted to power Cause: Wire harness/connector failure Temperature pot failure ATC module failure Possible failure modes: ATC module defaults to 72 o F (22 o C) setpoint. Solution: 1) Disconnect temperature pot and verify its operation. Its resistance should vary when rotated. Replace if faulty. 2) Inspect harness and connectors for possible shorting between temperature pot wires and other wires or possible open condition. If a short or open exists then replace harness. 3) If no fault found with temperature pot, wire harness, or connectors, then replace ATC module.

ATC Fault Code 122 Mode select pot open or shorted to power Cause: Wire harness/connector failure Mode pot failure ATC module failure Possible failure modes: ATC module (Manual Mode) - defaults to Defrost mode. ATC module (Automatic Mode) - defaults to Automatic mode. Solution: 1) Disconnect mode pot and verify its operation. Its resistance should vary when rotated. Replace if faulty. 2) Inspect harness and connectors for possible shorting between mode pot wires and other wires or possible open condition. If a short or open exists then replace harness. 3) If no fault found with mode pot, wire harness, or connectors, then replace ATC module. 50-1-21