Section 50 - Climate Control - Chapter 1 ATC Fault Code 125 High pressure switch (+) shorted to power Cause: Wire harness/connector failure NOTE: If system is properly charged, then the high pressure switch will be closed and the short could be on either leg of the switch. ATC module failure Possible failure modes: Compressor clutch disabled. Solution: 1) Inspect harness and connectors for possible shorting between high pressure switch wires (both leads) and other wires. If a short exists then replace harness. 2) If no fault found with wire harness, or connectors, then replace ATC module. ATC Fault Code 126 High pressure switch (+) shorted to ground Cause:
Wire harness/connector failure NOTE: If system is properly charged, then the high pressure switch will be closed and the short could be on either leg of the switch. ATC module failure Possible failure modes: Compressor clutch disabled. Solution: 1) Inspect harness and connectors for possible shorting between high pressure switch wires (both leads) and other wires. If a short exists then replace harness. 2) If no fault found with wire harness, or connectors, then replace ATC module. 50-1-22