CNH T8000 — AUTOMATIC TEMPERATURE CONTROL (ATC) OPERATION

Section 50 - Climate Control - Chapter 1 ATC Fault Code 127 High pressure switch (-) shorted to power Cause: Wire harness/connector failure NOTE: If system is properly charged, then the high pressure switch will be closed and the short could be on either leg of the switch. ATC module failure Possible failure modes: Compressor clutch disabled. Solution: 1) Inspect harness and connectors for possible shorting between high pressure switch wires (both leads) and other wires. If a short exists then replace harness. 2) If no fault found with wire harness or connectors, then replace ATC module. ATC Fault Code 128 High pressure switch (-) shorted to ground Cause: Wire harness/connector failure NOTE:

If system is properly charged, then the high pressure switch will be closed and the short could be on either leg of the switch. ATC module failure Possible failure modes: Compressor clutch disabled. Solution: 1) Inspect harness and connectors for possible shorting between high pressure switch wires (both leads) and other wires. If a short exists, then replace harness. 2) If no fault found with wire harness or connectors, then replace ATC module. 50-1-23