starting, the section area 36mm2 low voltage connecting cable should be adopted. battery and the starting motor to avoid the voltage drop too hard when the engine When the staring current is highest, for 12V and 24 V starting motor, the voltage drop should be less than o. 5V and 1V respectively. The battery with the diesel engine hasnt been charged before delivery, it-should be first charged as the battery"s requirement before used. When the diesel engine is working, the amount of the charging current should often be noticed. When the needle of the ammeter is reaching to zero, or shows that the battery has been fully charged and the charging circuit can be switched off.
The diesel engine adopts the JF series siticon rectified dynamo which has the char- The use of voltage regulator is to keep the voltage at the range of 13.5 -14. 5V or 27 acteristics of small volume, simple structure, low speed electrification etc. -29V respectively when the speed of the 14V or 28V generators adopt FTlll or FT211 voltage regulator respectively. If the charging' indicator is needed, the genera- tors should adopt FT126 or FT226 voltage regulator.
When the FTlll type and FT211 type regulators are used, the key switch should be turned off as soon as the engine stops in case the battery discharge to the magnetic coil and make the battery insuffi- cient, this will influence the next starting. The regulator is a precise instrument and not be dismantled and regulated at will, if The starting motor is full closed direct current series excitation motor. The working it is necessary to be adjusted, it should be done at special equipment. current of the starting motor is very larg'e, it can only works within a short time, and every starting time can't exceeds lOs.
if it"s necessary to continuously start, the break shouldnt less than 2 minutes and shouldnt exceed 10 times in case the start- The key switch has three working positions, at the center position, the whole circuit ing motor and the battery be damaged. will be turned off, turning the key clockwise, the preheating - starting switch, Volt- age regulator and other electric equipment will all be switched on and the diesel en- the end to turn off the preheating - starting switch and in Case of any trouble. gine wiH start. After the engine starts, the switch should be turned anticlockwise to If the pre - heater is used, a preheating - starting switch should be adopted.
The preheating - starting switch has four working positions. At the" Preheat ll position, only the pre - heater or electric plunger will be turned on. At the" Preheat - start" start" position, only starting motor will be turned on. To loose the switch, it will au- position, both the pre - heater and the starting motor will be turned on. At the" tomatically moves back to the" 0" position and the whole circuit will be cut off. 39