Komatsu — Replacing the Elements

Lubrication and Service - Section 40 OM4051 Page 40-4 AIR CLEANER SERVICE Replacing the Elements NOTE: The function of the safety element is to increase overall reliability and engine protection. If the safety element indicator shows red, the element has become clogged and should be replaced with a new one. The engine must be turned off before servicing the air cleaner assemblies or opening the engine air intake system. Never start the engine with the filter elements removed. Serious engine damage can result. 1. Turn off the engine. Clean any dirt and dust from the area around the element cover. 2. Loosen the clips on element cover (1, Figure 40-5) and remove the element cover.

Pull primary element (2) from air cleaner assembly (4). Inspect and empty the dust cups at regular intervals. Daily inspection is recommended. Never allow the dust level to build up to the tube (precleaner) chamber. 3. Inspect the primary element carefully for damage, holes or breaks which might affect reuse of the element. If the element appears serviceable, proceed with the cleaning procedure. If defects are found in the element, replace the element. During operation or after the engine has been turned off, observe the air filter restriction gauges mounted on the overhead panel in the cab. When a gauge shows maximum restriction, filter service is required.

Check all engine air inlet tubes, hoses and clamps. All connections must be air tight to prevent dirt from entering. Air cleaner housing fasteners and mountings must be tight. After the filters have been serviced, reset the air filter restriction gauges by pressing the reset button on the face of the gauge. See Figure 40-4. Have a new safety (secondary) filter element on hand before removing the used filter element. Do not keep the intake system open to the atmo- sphere any longer than necessary. 4. If the safety element must be replaced, remove and discard the safety element. Do not clean the damaged or dirty safety element. 5. Install the new safety element. 6.

Install primary element (2) into the air cleaner. If the original element is being reused, ensure the sealing gasket is not damaged. The gasket must seal completely. FIGURE 40-4. AIR FILTER RESTRICTION GAUGE 7. If open, close and latch dust cup valves (11) on the bottom of dust cups (10). 8. Install element cover (1) and latch the clips.