5) RELIEF VALVE The relief valves determine the drive force and the brake force for hydraulic excavator travel and are installed in the main port M1 and M2 lines. A shock less function is also incorporated to reduce shock produced at the start of both acceleration and deceleration. (1) ① ② The construction of the relief valve. A direct-acting differential area type relief valve A shockless piston The installation of a shockless type relief valve helps reduce. Shockless piston 8007A2TM16 (2) The relief valve operates in two stages as follows. ① First stage At the start of operation, the shockless piston moves to maintain the spring chamber at a low pressure.
Thus, the pressure receiving area of the poppet becomes the poppet seat area (S1), a considerably larger area than the pressure receiving area (S1- S2) at the specified relief setting. For this reason, the relief operating pressure is kept at a low pressure until the shockless piston completes its movement. The low pressure holding time depends on the poppet orifice diameter, the free piston pressure receiving area and the free piston stroke. S1 S2 8007A2TM15 2-68