Kaiyi — 5. TRAVEL SPEED CONTROL SYSTEM

GROUP 5 TRAVEL SPEED CONTROL SYSTEM Main control valve Travel motor Arm 1 Option Regulator Boom 2 Swing Travel(LH) Travel speed solenoid valve Engine Main pump Pilot pump Cluster Drive signal MCU Travel speed pilot lamp Travel speed switch signal CAN #1 & #2 900L5MS05 5-8 Arm 2 Bucket Boom 1 Travel(RH) Travel speed can be switched manually by pressing the travel speed switch on the cluster. Travel Speed solenoi speed Lamp d valve on cluster Operation Low O FF Turtle Low speed, high driving torque in the travel motor High O N Rabbit High speed, low driving torque in the travel motor ※ Default : Turtle (Low)