GROUP 4 POWER BOOST SYSTEM Main control valve Arm 1 Arm 2 Option Bucket Boom 2 Boom 1 Travel(LH) Swing Main relief valve pressure switch PS pressure switch PS Engine Power boost solenoid valve ECM Main pump Pilot pump Power boost button CAN #1 Pump power shift EPPR LH control lever Signal Drive signal Power max button signal MCU Pressure signal Haptic controller Emergency CLUSTER AIRCON OFF Power max pilot lamp Normal Power mode sw signal CN-16A CN-16B CN-16 CAN #1 & #2 CAN #2 Cluster 900L5MS04 · When the power boost switch on the left control lever knob is pushed ON, the power mode is set P mode and maximum digging power is increased by 10 %.
· When the power boost function is activated, the power boost solenoid valve pilot pressure raises the set pressure of the main relief valve to increase the digging power. When the auto power boost is set to Enable and power mode is set to P mode on the cluster, the digging power is automatically increased as working conditions by the MCU. It is operated max 8 seconds. 5-7 Travel(RH) Description Activated Canceled Condition Function Power boost switch : ON Multimodal dial : over 8 - Power mode : P - Multimodal dial power : 9 - Power boost solenoid : ON - Power boost pilot lmap : ON - Operating time : max 8 seconds Power boost switch : OFF - Pre-set power mode - Power boost solenoid :
OFF - Power boost pilot lamp : OFF