Kaiyi — 11. SELF-DIAGNOSTIC SYSTEM

G : General C : Crawler Type W : Wheel Type Some error codes are not applied to this machine. 5-18 DTC Diagnostic Criteria Application HCESPN FMI G C W 128 0 (when you had conditions mounting pressure sensor) 10 seconds continuous, Boom Down Pilot Press. Sensor Measurement Voltage > 5.2V ● 1 (when you had conditions mounting pressure sensor) 10 seconds continuous, 0.3V≤ Boom Down Pilot Press. Sensor Measurement Voltage ● 4 (when you had conditions mounting pressure sensor) 10 seconds continuous, Boom Down Pilot Press. Sensor Measurement Voltage ● (Results / Symptoms) 1. Monitor – Boom Down Pilot Press. display failure 2. Control Function – Boom floating operation failure (Checking list) 1.

CD-85 (#B) – CN-53 (#23) Checking Open/Short 2. CD-85 (#A) – CN-53 (#3) Checking Open/Short 3. CD-85 (#C) – CN-53 (#13) Checking Open/Short 129 0 10 seconds continuous, Arm In Pilot Press. Sensor Measurement Voltage > 4.8V ● 1 10 seconds continuous, 0.3V≤ Arm In Pilot Press. Sensor Measurement Voltage ● 4 10 seconds continuous, Arm In Pilot Press. Sensor Measurement Voltage ● (Results / Symptoms) 1. Monitor – Arm In Pilot Press. display failure 2. Control Function – IPC operation failure (Checking list) 1. CD-90 (#B) – CN-52 (#28) Checking Open/Short 2. CD-90 (#A) – CN-51 (#3) Checking Open/Short 3.

CD-90 (#C) – CN-51 (#13) Checking Open/Short 133 0 10 seconds continuous, Arm In/Out & Bucket In Pilot Press. Sensor Measurement Voltage > 5.2V ● 1 10 seconds continuous, 0.3V≤ Arm In/Out & Bucket In Pilot Press. Sensor Measurement Voltage ● 4 10 seconds continuous, Arm In/Out & Bucket In Pilot Press. Sensor Measurement Voltage ● (Results / Symptoms) 1. Monitor – Arm In/Out & Bucket In Pilot Press. display failure 2. Control Function – Engine variable horse power control operation failure (Checking list) 1. CD-35 (#B) – CN-52 (#14) Checking Open/Short 2. CD-35 (#A) – CN-51 (#3) Checking Open/Short 3. CD-35 (#C) – CN-51 (#13) Checking Open/Short