G : General C : Crawler Type W : Wheel Type Some error codes are not applied to this machine. 5-19 DTC Diagnostic Criteria Application HCESPN FMI G C W 135 0 10 seconds continuous, Swing Pilot Press. Sensor Measurement Voltage > 5.2V ● 1 10 seconds continuous, 0.3V≤ Swing Pilot Press. Sensor Measurement Voltage ● 4 10 seconds continuous, Swing Pilot Press. Sensor Measurement Voltage ● (Results / Symptoms) 1. Monitor – Swing Pilot Press. display failure 2. Control Function – IPC operation, Boom first operation failure (Checking list) 1. CD-24 (#B) – CN-52 (#36) Checking Open/Short 2. CD-24 (#A) – CN-51 (#3) Checking Open/Short 3.
CD-24 (#C) – CN-51 (#13) Checking Open/Short 138 0 Monitor – Select Attachment(breaker / crusher) 10 seconds continuous, Attachment Pilot Press. Sensor Measurement Voltage > 5.2V ● 1 Monitor – Select Attachment(breaker / crusher) 10 seconds continuous, 0.3V≤ Attachment Pilot Press. Sensor Measurement Voltage ● 4 Monitor – Select Attachment(breaker / crusher) 10 seconds continuous, Attachment Pilot Press. Sensor Measurement Voltage ● (Results / Symptoms) 1. Monitor – Attachment Pilot Press. display failure 2. Control Function – Option attachment flow control operation failure (Checking list) 1. CD-69 (#B) – CN-53 (#14) Checking Open/Short 2. CD-69 (#A) – CN-53 (#3) Checking Open/Short 3.
CD-69 (#C) – CN-53 (#13) Checking Open/Short 139 1 10 seconds continuous, 0.3V≤ Option Pilot Press. Sensor Measurement Voltage ● 4 10 seconds continuous, Option Pilot Press. Sensor Measurement Voltage ● (Results / Symptoms) 1. Monitor – Option Pilot Press. display failure 2. Control Function – Auto Idle operation failure (Checking list) 1. CD-100 (#B) – CN-52 (#21) Checking Open/Short 2. CD-100 (#A) – CN-51 (#3) Checking Open/Short 3. CD-100 (#C) – CN-1 (#6) Checking Open/Short