Kaiyi — 11. SELF-DIAGNOSTIC SYSTEM

G : General C : Crawler Type W : Wheel Type Some error codes are not applied to this machine. 5-20 DTC Diagnostic Criteria Application HCESPN FMI G C W 140 5 (Detection) (When Main Pump EPPR Current is more than 10 mA) 10 seconds continuous, Pump EPPR drive current ● 6 (Detection) 10 seconds continuous, Main Pump EPPR drive current > 1.0A (Cancellation) 3 seconds continuous, Main Pump EPPR drive current ≤ 1.0 A ● (Results / Symptoms) 1. Control Function – Pump horse power setting specification difference (Fuel efficiency/speed specification failure) (Checking list) 1. CN-75 (#2) – CN-52 (#9) Checking Open/Short 2.

CN-75 (#1) – CN-52 (#10) Checking Open/Short 141 5 (Model Parameter) mounting Boom Priority EPPR (Detection) (When Boom Priority EPPR Current is more than 10 mA) 10 seconds continuous, Boom Priority EPPR drive current ● 6 (Detection) 10 seconds continuous, Boom Priority EPPR drive current > 1.0 A (Cancellation) 3 seconds continuous, Boom Priority EPPR drive current ≤ 1.0 A ● (Results / Symptoms) 1. Control Function – Boom first control operation failure (Checking list) 1. CN-133 (#2) – CN-52 (#34) Checking Open/Short 2. CN-133 (#1) – CN-52 (#35) Checking Open/Short