Kaiyi — 11. SELF-DIAGNOSTIC SYSTEM

G : General C : Crawler Type W : Wheel Type Some error codes are not applied to this machine.

5-26 DTC Diagnostic Criteria Application HCESPN FMI G C W 181 4 (Model Parameter) mounting Reverse Cooling Fan Solenoid (Detection) (When Reverse Cooling Fan Solenoid is Off) 10 seconds continuous, Reverse Cooling Fan Solenoid drive unit Measurement Voltage ≤ 3.0V (Cancellation) (When Reverse Cooling Fan Solenoid is Off) 3 seconds continuous, Reverse Cooling Fan Solenoid drive unit Measurement Voltage > 3.0V ● 6 (Detection) (When Reverse Cooling Fan Solenoid is On) 10 seconds continuous, Reverse Cooling Fan Solenoid drive current > 4.5 A (Cancellation) (When Reverse Cooling Fan Solenoid is On) 3 seconds continuous, Reverse Cooling Fan Solenoid drive current ≤ 4.5 A ● (Results / Symptoms) 1.

Control Function – Cooling Fan reverse control operation failure (Check list) 1. CN-52 (#1) – CN-51 (#4) Checking Open/Short 2. CN-52 (#2) – CN-51 (#15) Checking Open/Short 188 5 (Detection) (When Attachment Flow EPPR 1 current is equal or more than 300 mA) 10 seconds continuous, Attachment Flow EPPR drive current ● 6 (Detection) 10 seconds continuous, Attachment Flow EPPR 1 drive current > 1.0 A (Cancellation) 3 seconds continuous, Attachment Flow EPPR 1 drive current ≤ 1.0 A ● (Results / Symptoms) 1. Control Function – IPC operation failure, Option attachment flow control operation failure (Checking list) 1. CN-242 (#2) – CN-52 (#39) Checking Open/Short 2.

CN-242 (#1) – CN-52 (#40) Checking Open/Short