G : General C : Crawler Type W : Wheel Type Some error codes are not applied to this machine. 5-27 DTC Diagnostic Criteria Application HCESPN FMI G C W 189 5 (Detection) (When Attachment Flow EPPR 2 current is equal or more than 300 mA) 10 seconds continuous, Attachment Flow EPPR drive current ● 6 (Detection) 10 seconds continuous, Attachment Flow EPPR 2 drive current > 1.0 A (Cancellation) 3 seconds continuous, Attachment Flow EPPR 2 drive current ≤ 1.0 A ● (Results / Symptoms) 1. Control Function – Option attachment flow control operation failure (Checking list) 1. CN-378 (#2) – CN-52 (#6) Checking Open/Short 2.
CN-378 (#1) – CN-52 (#7) Checking Open/Short 196 0 HW145 10 seconds continuous, Attachment flow control EPPR 1 press. Sensor Measurement Voltage > 5.2V 1 HW145 10 seconds continuous, 0.3V≤ Attachment flow control EPPR 1 press. Sensor Measurement Voltage 4 HW145 10 seconds continuous, Attachment flow control EPPR 1 press. Sensor Measurement Voltage (Results / Symptoms) 1. Control Function – Driving second pump joining function operation failure (Checking list) 1. CD-93 (#B) – CN-52 (#11) Checking Open/Short 2. CD-93 (#A) – CN-51 (#3) Checking Open/Short 3. CD-93 (#C) – CN-51 (#13) Checking Open/Short 200 0 10 seconds continuous, Pump EPPR Press.
Sensor Measurement Voltage > 5.2V ● 1 10 seconds continuous, 0.3V≤ Pump EPPR Press. Sensor Measurement Voltage ● 4 10 seconds continuous, Pump EPPR Press. Sensor Measurement Voltage ● (Results / Symptoms) 1. Monitor – Pump EPPR Press. display failure 2. Control Function – Pump input horse power control failure, Overload at compensation control operation failure (Fuel efficiency/speed performance failure) (Checking list) 1. CD-44 (#B) – CN-52 (#32) Checking Open/Short 2. CD-44 (#A) – CN-51 (#3) Checking Open/Short 3. CD-44 (#C) – CN-51 (#13) Checking Open/Short