G : General C : Crawler Type W : Wheel Type Some error codes are not applied to this machine. 5-35 DTC Diagnostic Criteria Application HCESPN FMI G C W 714 3 (Model Parameter) Mounting Acc. Dial 10 seconds continuous, Acc. Dial Measurement Voltage > 5.2V ● 4 (Model Parameter) Mounting Acc. Dial 10 seconds continuous, Acc. Dial Measurement Voltage ● (Results / Symptoms) 1. Monitor – Acc. Dial Voltage display failure 2. Control Function – Engine rpm control failure (Checking list) 1.
CN-7 (#15) – CN-52 (#23) Checking Open/Short 722 4 (Detection) (When Travel Alarm (Buzzer) Sound is Off) 10 seconds continuous, Travel Alarm (Buzzer) Sound Relay drive unit Measurement Voltage ≤ 3.0V (Cancellation) (When Travel Alarm (Buzzer) Sound Relay is Off) 3 seconds continuous, Travel Alarm (Buzzer) Sound Relay drive unit Measurement Voltage > 3.0V ● 6 (Detection) (When Travel Alarm (Buzzer) Sound is On) 10 seconds continuous, Travel Alarm (Buzzer) Sound Relay drive current > 4.5 A (Cancellation) (When Travel Alarm (Buzzer) Sound is On) 3 seconds continuous, Travel Alarm (Buzzer) Sound Relay drive current ≤ 4.5 A ● (Results / Symptoms) 1.
Control Function – Driving alarm operation failure (Checking list) 1. CN-81 (#1) – CN-52 (#31) Checking Open/Short 2. CN-81 (#2) – Fuse box (#28) Checking Open/Short 831 2 (When mounting the A/C Controller) 60 seconds continuous, A/C Controller Communication Data Error ● (Results / Symptoms) 1. Control Function – A/C Controller operation failure (Checking list) 1. CN-11 (#8) – CN-51 (#22) Checking Open/Short 2. CN-11 (#7) – CN-51 (#32) Checking Open/Short 840 2 60 seconds continuous, Cluster Communication Data Error ● (Results / Symptoms) 1. Control Function – Cluster operation failure (Checking list) 1. CN-56A (#7) – CN-51 (#22) Checking Open/Short 2.
CN-56A (#6) – CN-51 (#32) Checking Open/Short