Kaiyi — 11. SELF-DIAGNOSTIC SYSTEM

G : General C : Crawler Type W : Wheel Type Some error codes are not applied to this machine. 5-36 DTC Diagnostic Criteria Application HCESPN FMI G C W 841 2 10 seconds continuous, ECM Communication Data Error ● (Results / Symptoms) 1. Control Function – ECM operation failure (Checking list) 1. CN-16 (#6) – CN-51 (#21) Checking Open/Short 2. CN-16 (#7) – CN-51 (#31) Checking Open/Short 845 2 (When mounting the I/O Controller 1) 60 seconds continuous, I/O Controller 1 Communication Data Error ● (Results / Symptoms) 1. Control Function – I/O Controller 1 operation failure (Checking list) 1. CN-53 (#21) – CN-51 (#23) Checking Open/Short 2.

CN-53 (#31) – CN-51 (#33) Checking Open/Short 848 2 (When mounting the Haptic Controller) 60 seconds continuous, Haptic Controller Communication Data Error ● (Results / Symptoms) 1. Control Function – Haptic Controller operation failure (Checking list) 1. CN-8 (#2) – CN-51 (#22) Checking Open/Short 2. CN-8 (#3) – CN-51 (#32) Checking Open/Short 850 2 (When mounting the RMCU) 60 seconds continuous, RMCU communication Data Error ● (Resuluts / Symptoms) 1. Control Function – RMCU operation failure (Checking list) 1. CN-125A (#3) – CN-51 (#22) Checking Open/Short 2.

CN-125A (#11) – CN-51 (#32) Checking Open/Short 861 2 (When mounting the I/O Controller 2) 60 seconds continuous, I/O Controller 2 communication Data Error ● (Results / Symptoms) 1. Control Function – I/O Controller 2 operation failure (Checking list) 1. CN-53 (#21) – CN-51 (#23) Checking Open/Short 2. CN-53 (#31) – CN-51 (#33) Checking Open/Short