P A P Pilot oil supply line (pilot pressure) T Return to tank A Secondary pressure to flow regulator at main pump T 5-76 3)OPERATING PRINCIPLE (pump EPPR valve) (1) Structure 6 7 2 3 4 5 1 5-22(1) 1 Sleeve 2 Spring 3 Spool 4 O-ring 5 O-ring 6 Solenoid valve 7 Connector (2) Neutral Pressure line is blocked and A oil returns to tank. P A T P T A P T A 5-22(2) (3) Operating Secondary pressure enters into A. P A T