Kaiyi — 13. EPPR VALVE

2) EPPR VALVE CHECK PROCEDURE (1) Check electric current value at EPPR valve ① Disconnect connector CN-133 from EPPR valve. ② Insert the adapter to CN-133 and install multimeter as figure. ③ Start engine. ④ Set s-mode and cancel auto decel mode. ⑤ If rpm display approx 1650 ± 50 rpm disconnect one wire harness from EPPR valve. ⑥ Check electric current in case of combined boom up and swing operation. (2) Check pressure at EPPR valve Spec : 12~37 kgf/cm 2 (170~530 psi ) (combined boom up and swing operation) ① Remove hose from A5 port and connect pressure gauge as figure. · Gauge capacity : 0 to 50 kgf/cm 2 (0 to 725 psi ) Pressure gauge Plug ② Start engine.

③ Set s-mode and cancel auto decel mode. P1 A5 Solenoid valve ④ If rpm display approx 1650 ± 50 rpm check pressure (In case of combined boom up and swing operation). A1 A2 P2 P3 T P4 ⑤ If pressure is not correct, adjust it. Boom priority EPPR valve ⑥ After adjust, test the machine. 900L5MS24 5-79 Spe c : 400~600 mA (combined boom up and swing operation) P1 A5 Boom priority P2 P4 EPPR valve A1 A2 T P3 CN-133 Adapter Multimeter (P/no.:21Q6-50410) 900L5MS23