2. Boom priority EPPR valve 1) Composition The boom priority EPPR valve is built in a manifold and mainly consisting of valve body and coil. This EPPR valve installed under the solenoid valve. 2) Control The boom priority EPPR valve has to be controlled by a specific electronic amplifier card, which is supplying the coil with a current 580 mA at 30 Ω and 24 V. 3) Operating principle (1) Structure A 2 3 Control spool 21095MS14 P T A P : Pilot supply line T : Return to tank A : Secondary pressure to flow MCV (2) Operation In de-energized mode the inlet port (P) is closed and the outlet port (A) is connected to tank port (T).
In energized mode the solenoid armature presses onto the control spool with a force corresponding to the amount of current. This will set a reduced pressure at port A. The setting is proportional to the amount of current applied. (3) Maximum pressure relief If a pressure from outside is applied on port A the valve may directly switch to tank port (T) and protect the system before overload. 5-78 1 5 4 6 P T P T 1 O-ring 2 Support ring 3 Valve body 4 Coil 5 Connector 6 Cover cap