Kaiyi — 3. ELECTRICAL SYSTEM

GROUP 3 ELECTRICAL SYSTEM 1. WHEN STARTING SWITCH IS TURNED ON, CLUSTER DISPLAY DOES NOT APPEAR · Before disconnecting the connector, always turn the starting switch OFF. · Before carrying out below procedure, check all the related connectors are properly inserted and short of fuse No. 10. · After checking, insert the disconnected connectors again immediately unless otherwise specified. Check voltage CLUSTER BATT (24V) 1 11 FUSE POWER IG (24V) 2 10 No.10 GND 3 9 HAPTIC CONTROLLER CN-56A CN-5 6 1 POWER IG 7 CN-363 2 POWER BATT CN-8 900L6ES01 6-24 YES Check voltage YES between CN-56A (2) and (3) Check voltage Starting switch : ON between CN-5 Voltage : 20~32V NO (9) and (10) Starting switch :

ON Voltage : 20~32V NO Cause Remedy Defective cluster Disconnection in wiring harness or poor contact between CN-5-CN-56A Disconnection in wiring harness or poor contact between CN-5 (9 -GND or fuse No. 10 Replace Repair or replace (after clean) Repair or replace (after clean) ) YES 20~32V NO 0V