5. Malfunction of pump 1 pressure sensor · Fault code : HCESPN 120, FMI 0~4 Before carrying out below procedure, check all the related connectors are properly inserted. 1) INSPECTION PROCEDURE 6-47 Cause Remedy YES Defective MCU Replace YES Short circuit or Replace or repair poor connection Check voltage YES between CN-52- between CN-1 (29)-CN-1 (5) (5)-GND eck voltage Spec : 1~5V Detective P1 Replace or repair ween CN-52 NO Check voltage Actuator operating pressure sensor ) - GND YES between CD-42 Short circuit or Replace or repair c : 1~5V (A)-(C) poor connection ator operating between CN-1 TEST 9 Spec : 24±2V (5)-CD-42 (B) Starting switch :
ON Check voltage Short circuit or Replace or repair NO between CN-1 poor connection NO (4)-(6) between CD-42 (A)-CN-1 (4) or Spec : 24±2V CD-42 (C)-CN-1 Starting switch :
ON (6) Short circuit or Replace or repair NO poor connection between CN-1 (4)-CN-51 (3) or CN-1 (6) - CN-51 (13) ing diagram CN-51 CD-42 SENSOR 24V 3 4 A SUPPLY 5 B SIG GROUND(SENSOR) 13 6 C RETURN PUMP 1 PRESSURE SENSOR MCU CN-1 P1 PRESSURE SENSOR 29 CN-52 900L6MS35 Cause Remedy Defective MCU Short circuit or poor connection between CN-52- (29)-CN-1 (5) Detective P1 pressure sensor Short circuit or poor connection between CN-1 (5)-CD-42 (B) Short circuit or poor connection between CD-42 (A)-CN-1 (4) or CD-42 (C)-CN-1 (6) Short circuit or poor connection between CN-1 (4)-CN-51 (3) or CN-1 (6) - CN-51 (13) Replace Replace or repair Replace or repair Replace or repair Replace or repair Replace or repair CN-51 CD-42 SENSOR 24V 3 4 A SUPPLY 5 B SIG GROUND(SENSOR) 13 6 C RETURN PUMP 1 PRESSURE SENSOR MCU CN-1 P1 PRESSURE SENSOR 29 CN-52 900L6MS35 900L6MS35