Kaiyi — 4. MECHATRONICS SYSTEM

2) TEST PROCEDURE (1) Test 7 : Check voltage at CN-52 (38) and ground. Prepare 1 piece of thin sharp pin, steel or copper. Insert prepared pin to rear side of connectors : One pin to (38) of CN-52. Starting switch ON. Check voltage as figure. ① ② ③ ④ (2) Test 8 : Check voltage at CN-52 (37) and ground. Prepare 1 piece of thin sharp pin, steel or copper Insert prepared pin to rear side of connectors : One pin to (37) of CN-52. Starting switch ON. Check voltage as figure. ① ② ③ ④ 6-46 SPEC : Actuator operating :

1~5 V MCU PIN CN-51 CN-52 10 9 8 7 6 5 4 3 2 1 CN-52 Female 20 11 30 21 38 4039383736 34333231 GROUND Multimeter 10 9 8 7 6 5 4 3 2 1 CN-52 Female 20 11 30 21 37 4039383736 3534333231 GROUND Multimeter 300L6MS04