4. AUTO DECEL SYSTEM DOES NOT WORK · Fault code : HCESPN 105, FMI 0~4 (work pressure sensor) HCESPN 108, FMI 0~4 (travel oil pressure sensor) Before carrying out below procedure, check all the related connectors are properly inserted. 1) INSPECTION PROCEDURE Wiring diagram CN-51 SENSOR 24V 3 CD-6 A SUPPLY B SIG GROUND(SENSOR) 13 TRAVEL PRESSURE SENSOR C RETURN MCU TRAVEL PS 38 CD-7 WORKING PS 37 A B SUPPLY SIG C RETURN CN-52 WORK PRESSURE SENSOR 900L6MS33 6-45 YES YES Check voltage NO between CD-6(A) and (C) NO ck voltage Spec : 24±2V een CN-52 Starting switch ON -GND and 52(37)-GND : 1~5V tor operating EST 7, 8 YES Check voltage between CD-7(A) NO and (C) NO Spec :
24±2V Starting switch ON Cause Remedy Defective MCU Defective travel pressure switch Short circuit or poor connection between CN-51 (3) -CD-6 (A) and / or CN-51 (13)-CD-6 (C) (fault code 108 displayed) Defective work pressure sensor Short circuit or poor connection between CN-51 (3)-CD-7 (A) and / or CN-51 (13)-CD -7 (C) (fault code 105 displayed) Replace Replace Replace or repair Replace Replace or repair