Kaiyi — 4. MECHATRONICS SYSTEM

3. MALFUNCTION OF CLUSTER OR MODE SELECTION SYSTEM Before carrying out below procedure, check all the related connectors are properly inserted.

1) INSPECTION PROCEDURE Wiring diagram BATT.24V IG 24V MCU GND CAN1 HI CAN1 LO CAN2 HI 6 6 22 CAN2 HIGH CAN2 LO 7 5 32 CAN2 LOW RS-232 RX RS-232 TX CN-56A CN-5 1 BATT POWER 24V AUX LEFT CN-51 AUX RIGHT AUX GND FUSE CLUSTER No.6 900L6MS03 6-44 YES See if all lamps off on the MCU YES case YES Y R G HCESPN Y R G ctive fault NO on the LCD NO Y R G NO OK Check connection between CN-51 ⓐ (22) - CN-56A (6) or CN-51 (32) - CN-56A (7) NO Cause Remedy No power supply to the MCU MCU failure ⓐ Cluster failure No connection Check fuse No.6 Replace Replace Check and repair