2) TEST PROCEDURE (1) Test 4 : Check electric current at EPPR valve. Disconnect connector CN-75 from EPPR valve. Insert the adapter to CN-75 and install multimeter as figure. Start engine. Set S-mode and cancel auto decel mode. Position the accel dial at 10. If rpm show approx 1650 ± 50 rpm disconnect one wire harness from EPPR valve. Check electric current at bucket circuit relief position. Adapter(P/no.:21Q6-50410) CN-75 ① EPPR valve ② Multimeter ③ ④ ⑤ ⑥ Main pump 900L5MS21 ⑦ (2) ① Test 5 : Check pressure at EPPR valve. Remove plug and connect pressure gauge as figure. · Gauge capacity : 0 to 50 kgf/cm 2 (0 to 725 psi ) Start engine. Set S-mode and cancel auto decel mode.
Position the accel dial at 10. If rpm show approx 1650 ± 50 rpm check pressure at relief position of bucket circuit by operating bucket control lever. If pressure is not correct, adjust it. After adjust, test the machine. ② ③ ④ ⑤ ⑥ ⑦ 6-43 SPEC : 2~25 kgf/cm2 (30~350 psi) Pressure adjusting screw locknut EPPR valve Pilot pressure supply line 900L5MS22