13. MALFUNCTION OF POWER MAX Fault code : HCESPN 166, FMI 4 or 6 · Before carrying out below procedure, check all the related connectors are properly inserted. 1) INSPECTION PROCEDURE normal? SPEC Wiring diagram CN-52 POWER BOOST SOL 2 CN-88 MCU POWER MAX SOLENOID POWER BOOST SW 18 5 13 GROUND(SENSOR) 6 FUSE No.28 CN-51 CS-29 CN-4 1 2 POWER MAX SWITCH 900L6MS54 6-63 YES Check resistance YES between CN-88 (1)-(2) Check resistance YES SPEC: 15-35Ω between CN-51 NO See TEST 19 (18)-GND SPEC : age between Power max button (2)-GND pressed ON : 0Ω NO l? pressed OFF : ∞Ω switch ON : 24±1V switch OFF :
0V ST 18 NO Cause Remedy Short circuit or poor connection between CN-88 (1)-CN-52 (2) Defective power max. solenoid valve Check hydraulic system Short circuit or poor connection between CN-51 (18)-CS-29 (1) Short circuit or poor connection between CN-88 (2)- Fuse No. 28 Repair or replace Repair or replace Repair or replace Repair or replace 1 2