Travel mode switch : · 1 speed 2 speed Measure the travel speed selecting pressure in the Hi or Lo mode. Lower the bucket to the ground to raise the track off the ground. Operate the travel lever at full stroke and measure the fast speed pressure. Repeat steps ② and ③ three times and calculate the average values. ② ③ ④ (3) Evaluation The average measured pressure should be within the following specifications. Unit : kgf / cm 2 7-17 1 4) FOR TRAVEL SPEED SELECTING PRESSURE: P 900L7MS13 Model Travel speed mode Standard Maximum allowable Remarks X900 L 1 Speed 0 - 2 Speed 40±5 -