Komatsu — EVERY 4000 HOURS MAINTENANCE

. MAINTENANCE MAINTENANCE PROCEDURE 4 - 81 CHECK FOR MISSING FUEL SPRAY PREVENTION CAP, HARDENING OF RUBBER Fue l spray prevention caps (1) - (16) and fuel spray prevention cover (17) are protective parts installed to prevent fire caused by fuel leaking and spraying out o n to high temperature parts of the engine. Check visually that t here are no missing caps or loose bolts, and feel w ith your finger to check that the rubber has not hardened. If the re is any problem, t he problem part must be replac ed. Contact your Komatsu distributor fo r part replacement CHECK OPERATING CONDITION OF CO Ask your Komatsu distributor to carry out the