MAN Nutzfahrzeuge — Connector designation: MES 0 Reference pin: BATT- (18, 19)

113 3.6Fuel-delivery control circuit Plug connection: 1, 2 Function group: Switching output to BATT– Connector designation: MES 0 Reference pin: BATT– (18, 19) Description of output Characteristic parameter Conditions Dim. Min. Typ. Max. EMC capacitor Output voltage LOW status Output current Current limitation Switching edges Rise time Fall time C EMC U oL U oH I o I oK t r t f ON, at 11 A OFF I =20 mA o Output stage dis- abled Peak value R =10 kW L C =10 nF L nF V V mA A ms ms 2.4 3.0 1.2 BATT+ 10 1 4.4 1.8 V BATT+ 1.5 V 5 18 70 Remarks: This output stage is designed for operation together with the fuel delivery regulator of the injection system.

The effective current value is determined by the duty factor of the output stage transistor, the battery voltage and the fuel delivery regulator (R, L). This signal controls the position of the control rod (see RWG M, Y, R).