114 Plug connection: 9 Function group: Control rod position evaluator circuit Connector designation: RWG-M Description of output Characteristic parameter Conditions Dim. Min. Typ. Max. EMC capacitor Output voltage Alternating voltage compo- nent Direct voltage component Output frequency Short-circuit protection C EMC U AC U DC f U KS With sensor at 6 mm control rod travel With sensor max. 1 min. nF V pp V kHz V 1.2 –1 1.5 2.6 3.0 10 2.2 26 Remarks: – Control rod position transducer with pick-off instrument coil – A sinusoidal alternating voltage (to RWG-R in phase opposition) with superimposed direct voltage can be measured with the sensor connected.
– The inductive position sensor for the control rod in the injection system is evaluated via the 3 plug connections RWG-M, R and Y. A voltage proportional to the control position is made available in the control unit. – Regulations concerning the installation of cables – particularly with regard to the capacitance per unit length – must be complied with.