MAN Nutzfahrzeuge — Boost pressure sensor

Testing Boost pressure sensor Flash code: 5x short Fault indication: Fault is indicated by the EDC indicator lamp coming on continuously Fault path: Boost pressure sensor Signal too high Signal too low Signal implausible with atmospheric pressure sensor (in control unit) Effect of fault: 60 to 70 % reduction in power Possible cause: Line braek, short-circuit to ground, boost pressure sensor faulty, control unit faulty Test precondition: EDC control unit connected Corrective measures Ignition switched on 33 Test Measurement Corrective measures Power supply Measure voltage at socket box across pin 33 (+) and pin 13 (–) Set-point value:

4,75–5,25 V – Check lines – Check plug connections – If no fault found, replace control unit (disconnect the control unit on ly w hen the curren t is sw it- ched off) Signal voltage Measure voltage at socket box across pin 36 (+) and pin 13 (–) Set-point value: Lower Idle speed: 0,94–1,20 V Upper Idle speed: 1,10–1,70 V If all the values are OK, the atmospheric pressure sensor in the control unit may be faulty – Replace control unit (only di- sconnect control unit once the current is switched off)