MAN Nutzfahrzeuge — Control rod position sensor

Testing Control rod position sensor Flash code: 6x short Fault indication: Fault is indicated by the EDC indicator lamp coming on continuously Fault path: Control rod position sensor Signal too high Signal too low Effect of fault: This fault results in the engine being shut down by setting the control rod tra- vel to 0. The engine cannot be started if this fault is currently present (EDC indicator lamp permanently on). Possible cause: Line break, short-circuit to ground, too little capacitance reserve, control rod position sensor set incorrectly, injection pump faulty Test precondition:

EDC control unit disconnected Socked box connected 34 Test Measurement Corrective measures Instrument coil Measure resistance at socket box across pin 11 and pin 9 Set-point value: 18–25 Ω – Check lines – Check plug connections – If no fault found, repair injection pump Reference coil Measure resistance at socket box across pin 11 and pin 10 Set-point value: 18–25 Ω Measure resistance at socket box across pin 18 and pin 9 Set-point value: > 10 MΩ Measure resistance at socket box bet- ween pin 18 and pin 10 Set-point value: