Testing Coolant temperature sensor Flash code: 7x short Fault indication: Fault is indicated by the EDC indicator lamp coming on continuously Fault path: Coolant temperature sensor Effect of fault: The substitute value provided in the control unit for such cases results in a reduction in power output (e.g. in the event of radiator contamination or failure of cooling system). Possible cause: Line break, short-circuit, temperature sensor faulty, control unit faulty, failure or contamination of cooling system. Test precondition:
EDC control unit disconnected Socked box connected 35 Test Measurement Corrective measures Sensor resistance (control unit disconnec- ted) Measure resistance at the socket box across pin 53 and pin 13 Set-point value: 1.3–3.6 kΩ at 15–30°C 230–460 Ω at 75–80°C – Check lines – Check plug connections – Replace temperatur sensor – If no fault found, replace control unit (disconnect the control unit only when the current is swit- ch e d off) Sensor voltage (control unit connected) Measure voltage at socket box between pin 53 and pin 13 Set-point value: 3,46–1,22 V at 30–90°C