MAN Nutzfahrzeuge — Start of injection control deviation / Pilot stroke regulator

Testing Start of injection control deviation / Pilot stroke regulator Flash code: 1x long, 8x short Fault indication: Fault is indicated by the EDC indicator lamp coming on continuously Fault path: Start of injection regulator control deviation Effect of fault: Reduced full load quantity Reduction in power output Possible increased smoke emissions The set-point actual value comparison of the pilot stroke regulator has resulted in a control deviation which has exceeded a specified time threshold. The system switches from closed-loop control to open-loop control with a fixed pre-set start of injection map. Possible cause:

Line break, short-circuit, plug connections to injection pump / bulkhead / con- trol unit: oxidised, expanded, pushed back, damagedneedle movement sensor faulty, rpm sensor faulty, fault in fuel system (leaking, clogged, air in system), air cleaner (clogged, faulty), injection pump faulty (internal fault in regulator or stiff movement) Test precondition: Socked box connected Note: When this fault occurs, always check the needle movement sensor and rpm sensor function paths, even if there is no corresponding fault in the fault me- mory. 43 Test Measurement Corrective measures Actuating solenoid Measure resistance at the socket box across pin 15 and pin 3 and pin 16 and pin 4 Set-point value:

1,2–2,0 Ω Measure resistance at the socket box across pin 18 and pin 3 Set-point value: > 10MΩ – Check lines – Check plug connections – If no fault found, replace injec- tion pump Needle movement sen- sor see needle movement sensor test see needle movement sensor test rpm sensor see rpm sensor test see rpm sensor test