MAN Nutzfahrzeuge — Needle movement sensor (NBF)

Testing Needle movement sensor (NBF) Flash code: 1x long, 10x short Fault indication: Fault is indicated by the EDC indicator lamp coming on continuously Fault path: Needle movement sensor not enough pulses too many pulses internal resistance incorrect Effect of fault: Reduced full load quantity Reduction in power output The system switches from closed-loop mode to open-loop mode with a fixed, pre-set start of injection map. If the fault is no longer present, the system will switch back to normal closed- loop control. Possible cause: Line break, short-circuit to ground, Needle movement sensor faulty Test precondition: Socked box connected Other possible causes:

Faulty pulses from the rpm sensor (including without fault message) Interference pulses between control unit and needle movement sensor (e.g. from switching relays) Needle movement sensor affected by structure-borne noise resulting from mechanical damage (e.g. valve gear, pistons) Jamming nozzle needle Fault in the fuel low pressure system caused by faulty or incorrect overflow valve, air or leaks in the sys- tem, faulty safty relay, faulty fuel pump, clogged filters or faulty injection pump 44 Test Measurement Corrective measures Internal resistance Measure the resistance at the socket box across pin 32 and pin 17 Set-point value:

90–130 Ω – Check lines – Check plug connections – Replace needle movement sen- sor