Testing Resistance bank (control unit Pin 35) Flash code: 1x long, 12x short Fault indication: Fault is not indicated by the EDC indicator lamp Fault path: Multistage switch for engine speed reduction Voltage to high Voltage to low Wrong voltage Effect of fault: None with standard circuit Function: Voltage signals are ascertained via the multistage input (control unit pin 35), their values are determined by external resistor interrupters in the EDC control box. Possible cause: Line break, short-circuit, resistor bank defective, control unit defective Test precondition:
EDC control unit disconnected Socked box connected 46 Test Measurement Corrective measures Resistor bank Measure resistance at the socket box across pin 35 and pin 13 Set-point value: Torque limit inaktiv: 0,4–0,7 kΩ Torque limit aktiv: 6,2–11,6 kΩ The fault also occurs when the resistance is 0 Ω or ∞ Ω Check lines – Check plug connections – Replace EDC control box