MAN Nutzfahrzeuge — Resistor bank

Testing Resistor bank Flash code: 1x long, 13x short Fault indication: Fault is not indicated by the EDC indicator lamp Fault path: Control box faulty Voltage values incorrect or implausible Effect of fault: The idle position can no longer be activated. If the fault was only temporary (e.g. operating unit activated several times) the system will be ready for operation after switching the ignition” off an on again. Function: The operating unit is resistor-coded, i.e. the control unit recognizes each swit- ching state according to the voltage level supplied.

Faults are detected when incorrect values are output over a certain period of time; Under certain condi- tions this fault may not be detected. Possible cause: Line break, short-circuit, EDC control box faulty, incorrect operation Test precondition: EDC control unit connected socket box connected ignition switched on 47 Test Measurement Corrective measures Control box Measure voltage at socket box between pin 44 and pin 13 Switch through all settings of the opera- ting unit and determine relevant voltage value Set-point value:

Not actuated 3,15 – 3,55 V – Check lines – Check plug connections – Replace the control box – If no fault found, replace control unit as a check (disconnect the control unit only when the cur- rent is switched off)