Testing Atmospheric pressure sensor (in control unit) Flash code: 2x long, 8x short Fault indication: Fault is indicated by the EDC indicator lamp coming on continuously Fault path: Atmospheric pressure sensor in control unit faulty Effect of fault: The power reduction at high altitudes for the protection of the exhaust turbo- charger is not activated Possible cause: Control unit faulty 50 Test Measurement Corrective measures Control unit If only this fault code is stored in the me- mory, testing is not possible, as the sen- sor is located in the control unit.
If, however, a faulty boost pressure sen- sor is also detected, this should be chek- ked first in accordance with the boost pressure sensor test (page 33). – Replace control unit (only di- sconnect control unit once the current is switched off)