MAN Nutzfahrzeuge — Safety relay

Testing Safety relay Flash code: 3x long, 1x short Fault indication: Fault is indicated by the EDC indicator lamp coming on continuously Fault path: Safety relay Effect of fault: Engine is shut down Engine will not start Function: The safety relay performs an important safety function in its capacity as an independent, higher-ranking (redundant) engine shut-off device The safety relay is activated in certain emergency situations when the engine can no longer be shut off by controlling fuel delivery to zero – e.g. when the control rod has jammed. The safety relay interrupts the positive power supply (pins 15 and 16) to the quantity magnet. Possible cause: Possible cause:

Line break, short-circuit, safety relay defective, faulty activa- tion from control unit (control unit defective) Test precondition: Socked box connected Note: When bleeding the fuel system using the presupply pump, power must be supplied to the safety relay, i.e. the fuel system cannot be bled without the ”ignition” being switched on! See page 25 for function test. Note: When bleeding the fuel system using the presupply pump, power must be supplied to the safety relay, i.e. the fuel system cannot be bled without the ”ignition” being switched on! See page 25 for function test.

52 Test Measurement Corrective measures Check Safety relay Start engine and let it idle Pull off bridge at pin 14 on test box Engine must stop within approx. 3 seconds a) EDC pin 14 and pin 24 (relay K2) Set-point value: 30–70 Ω b) EDC pin 19 and pin 21 (relay K2) Set-point value: [0 Ω – Check line – Check plug connection – Replace safety relay Power supply Switch on “ignition” Measure voltage at socket box across pin 14 (+) and pin 19 (–) Set-point value: U-Batt – Check line – Check plug connection – Replace safety relay If no fault found:

– Replace control unit Coil resistance Safety relay Switch off ”ignition” Disconnect control unit Measure resistance at socket box across Pin 14 and Pin 19 Set-point value: 240–300 Ω – Check line – Check plug connection – Replace safety relay